Models UVC26 and UVC27—
Galvanized Steel Damper

These dampers are designed for "in duct" mounting. The airfoil roll-formed blades and roll-formed frame are capable of withstanding differential pressures of 6 in. wg and velocities up to 4,000 fpm at its maximum panel width. For higher pressures and velocities, refer to limitation table.

Model UVC26
Model UVC27
Model UVC26
Parallel Blade
Model UVC27
Opposed Blade



Options for the UVC26 and UVC27

Bearings: OIB, stainless steel

Actuators: manual, electric and pneumatic actuators mounted on either side, and inside or outside the airstream

Factory-assembled jackshafting up to 48 sq ft

On-blade drive brackets for internal operation

Mounting holes


Standard Specifications for the UVC26 and UVC27

Max. Face Velocity
4000 fpm
Max. Differential
Pressure
6 in. wg
Max. Temperature
150°F
Dimensions
"A" and "B" dimensions are opening sizes. Dampers will be fabricated 1/4" undersize.
Min. Panel Size
8"W x 8"H (Parallel)
8"W x 12"H (Opposed)
Max. Panel Size
48"W x 60"H
Max. Size
Single Section: 48"W x 60"H
Multiple Section: 96"W x 60"H
(2W x 1W) or 48"W x 120"H
(1W x 2H).
Max. Configuration
Per Actuator
Two sections high or two sections wide
Frame

5 1/2" X 7/8" X 16 gauge galvanized steel hat channel

Blades
Double-skin galvanized steel construction with single-lock seam, airfoil shaped stronger than 14 gauge equivalent, 6 1/4" wide (including edge seals) by a minimum of 1/2" thick at the center. Depending upon the damper height, a variable-width blade may be required which will extend to a maximum of 3 1/4" from either the front or back of the damper. If the exact dimension of this variable blade is critical, contact McGill AirFlow.
Seals
Dual durometer vinyl (high-impact PVC) on blade edges and metallic compression type at jambs
Axles
1/2" square plated steel stub, mechanically locked to the blades
Bearings
Non-metallic celcon
Stops
Galvanized steel angle
Linkage
In-jamb type, plated steel angle and crank plates, and stainless steel pivots
Finish
Mill
Actuator
6" extended shaft. Dampers more than one panel wide or high, and operated with one actuator, must be jackshafted.

UNI-GASKET fittings

 


McGill AirFlow's Volume Dampers, Models:

UVC1/UVC2
UVC8/UVC9
UVC20/UVC21
UVC26/UVC27
UVC30/UVC31
UVC22/UVC23/UVC24/UVC25
UVC561/UVC562/UVC563

 


© 2002-2008 McGill AirFlow LLC
An enterprise of United McGill Corporation—Family owned and operated since 1951

Unless otherwise noted, all (™) trademarks and (®) registered trademarks are property of United McGill Corporation.